Back to the "Multiple platform build/check report" A  B  C  D  E [F] G  H  I  J  K  L  M  N  O  P  Q  R  S  T  U  V  W  X  Y  Z 

BioC 2.13: BUILD report for flowQ on moscato1

This page was generated on 2014-03-11 09:49:10 -0700 (Tue, 11 Mar 2014).

Package 259/750HostnameOS / ArchBUILDCHECKBUILD BIN
flowQ 1.22.1
Mike Jiang
Snapshot Date: 2014-03-10 16:20:24 -0700 (Mon, 10 Mar 2014)
URL: https://hedgehog.fhcrc.org/bioconductor/branches/RELEASE_2_13/madman/Rpacks/flowQ
Last Changed Rev: 85451 / Revision: 87282
Last Changed Date: 2014-01-11 17:19:32 -0800 (Sat, 11 Jan 2014)
zin1 Linux (Ubuntu 12.04.4 LTS) / x86_64  OK  OK 
moscato1 Windows Server 2008 R2 Enterprise SP1 (64-bit) / x64 [ ERROR ] skipped  skipped 
perceval Mac OS X Snow Leopard (10.6.8) / x86_64  ERROR  skipped  skipped 

Summary

Package: flowQ
Version: 1.22.1
Command: chmod a+r flowQ -R && D:\biocbld\bbs-2.13-bioc\R\bin\R.exe CMD build --keep-empty-dirs --no-resave-data flowQ
StartedAt: 2014-03-11 00:01:47 -0700 (Tue, 11 Mar 2014)
EndedAt: 2014-03-11 00:02:35 -0700 (Tue, 11 Mar 2014)
EllapsedTime: 48.5 seconds
RetCode: 1
Status:  ERROR  
PackageFile: None
PackageFileSize: NA

Command output

* checking for file 'flowQ/DESCRIPTION' ... OK
* preparing 'flowQ':
* checking DESCRIPTION meta-information ... OK
* installing the package to build vignettes
* creating vignettes ...Warning: running command '"D:/biocbld/bbs-2.13-bioc/R/bin/i386/Rscript" --vanilla --default-packages= -e "tools::buildVignettes(dir = '.', tangle = TRUE)"' had status 1
 ERROR
Loading required package: BiocGenerics
Loading required package: parallel

Attaching package: 'BiocGenerics'

The following objects are masked from 'package:parallel':

    clusterApply, clusterApplyLB, clusterCall, clusterEvalQ,
    clusterExport, clusterMap, parApply, parCapply, parLapply,
    parLapplyLB, parRapply, parSapply, parSapplyLB

The following object is masked from 'package:stats':

    xtabs

The following objects are masked from 'package:base':

    Filter, Find, Map, Position, Reduce, anyDuplicated, append,
    as.data.frame, as.vector, cbind, colnames, duplicated, eval, evalq,
    get, intersect, is.unsorted, lapply, mapply, match, mget, order,
    paste, pmax, pmax.int, pmin, pmin.int, rank, rbind, rep.int,
    rownames, sapply, setdiff, sort, table, tapply, union, unique,
    unlist

Loading required package: outliers
Loading required package: lattice
Loading required package: flowViz
Loading required package: flowCore

Attaching package: 'flowCore'

The following object is masked from 'package:BiocGenerics':

    normalize

KernSmooth 2.23 loaded
Copyright M. P. Wand 1997-2009
Loading required package: mvoutlier
Loading required package: sgeostat
Loading required package: bioDist
Loading required package: Biobase
Welcome to Bioconductor

    Vignettes contain introductory material; view with
    'browseVignettes()'. To cite Bioconductor, see
    'citation("Biobase")', and for packages 'citation("pkgname")'.

Loading required package: KernSmooth
Loading required package: parody
Loading required package: tools
Loading required package: RColorBrewer
Loading required package: latticeExtra

Attaching package: 'latticeExtra'

The following object is masked from 'package:flowViz':

    ecdfplot

Warning: replacing previous import by 'flowCore::normalize' when loading 'flowQ'
Warning: replacing previous import by 'flowCore::sort' when loading 'flowQ'
Warning: replacing previous import by 'methods::as' when loading 'flowQ'
Using ImageMagic library at NA
(version NA)

Invalid Parameter - 350x350
Warning: running command 'convert -resize 350x350 "D:/biocbld/bbs-2.13-bioc/tmpdir/RtmpMNX7ic/flowQ/images/uGckYIMrdl/summary.pdf" "D:/biocbld/bbs-2.13-bioc/tmpdir/RtmpMNX7ic/flowQ/images/uGckYIMrdl/bbs-2.jpg"' had status 4

Error: processing vignette 'DataQualityAssessment.Rnw' failed with diagnostics:
 chunk 1 (label = cellnum) 
Error in validProcess(.Object) : 
  No image files available. Check file paths
Execution halted